Re: and then...

[ SET Forum ] [ Help ]

Posted by Damir [ 213.202.104.131 ] on March 16, 2006 at 13:55:30:

In Reply to: Re: and then... posted by manualblock on March 16, 2006 at 07:51:59:

Well, the operating point you choose (Uak/Ia/Ugk) for a given tube determined your primary load impedance. (The term "primary winding resistance" is better used for the "static" DC resistance of the wire).
But, practice teach us that it`s only the beginning, a reccomendation.
Yes, we have the "standard" SE impedances, mostly - for 300B it is about 2k5, 3k, 3k5, 5k, or so. In principle, with higher values (with the same OP) we`d have a little larger damping factor, lower distortion, but lower power.
But, the main difference, IMO, is the quality of concrete device, and not (for example) 3k/3k5 difference. It is complex subject, really - there are books written about OPTs and tube/OPT interactions.
The best, (IMO, again) what "average DIY-er" can do is to buy quality OPT with various taps and trying for yourself various connections / OPs. (For example, "Lundahl" LL1620 or 1623.)



Replies:



[ SET Forum ] [ Help ]