Is cap size worth increasing in heater PS?

[ GroupBuild Forum ] [ Help ]

Posted by colinhester [ 65.186.5.10 ] on March 04, 2005 at 14:18:03:

In Reply to: That's what I used posted by Tnuctipun on March 04, 2005 at 09:29:28:

From a PSU simulation, it looks like ripple is really reduced by increasing the size of the capacitor that is closer to the diodes - not quite as much as the LCRC but still reduced. In your opinion would it be worth John replacing the first cap with the 2 10uF in parallel and using one of his 4.7uF in the second position. I'm thinking of adding a 10uF in parallel across the 4.7uF I already have installed, giving a total capacitance of 14.7uF.....Colin