Posted by Tnuctipun [ 64.12.116.14 ] on February 11, 2005 at 15:29:03:
In Reply to: Pretty happy and questions posted by colinhester on February 11, 2005 at 13:50:18:
Well, you can sort them with an Ohm-meter.
400-325-250-0-250-325-400 will all have continuity. that's 7 of the many.
The 5 and 6.3 are going to be near 0 Ohms( and I think youse got them center tapped, so the remaining pair of three wires with common continuity will be the filament windings). If I remember correctly, and the filament windings are CT, then the only single pair continuity will be the line/input.
Apply votlage to this one slowly with a pigtail and a Variac and confirm voltages with a *FEW* VAC input at first. You don't want to try putting 120V on a 5V winding...
Make a drawing and record your measurements. Don't loose the drawing!
regards,
Douglas