Posted by manualblock [ 69.112.69.86 ] on March 09, 2005 at 17:48:50:
O'kay; rookie mistake on the blowing fuse saga. While I wrapped the ends of the secondaries two tiny threads were touching inside one wrap; shorted secondaries, wouldn't you know it. Thanks be to the powers that be the trans did not fry.
So now we have lift-off. Good tube voltages and power out voltages. Except I have 300V on B+; is that normal. Next up is hook-up. I have pics too; I'll post after you C-Man.
After troubleshooting this I can wire the PS in my sleep.
I would like to say there is a need for a directory; witness the 5V on the heaters we both thought was correct. Also nice to have the secondary voltages listed again.